Required CCU firmware version: ≥ 3.87.6
sha256: bfbaaff13bf75295f81ec7fdd67cffa871c9106c94de0e23e9a7c50c052add6e
C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIPW-FIO6 - Homematic IP Wired IO Module flush-mount - 6 channels
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.4.4 - 2025-10-06
** Bugfix
- Alarm backup is not send if the initiating input channel has link partners in addition to the SHC
Version 1.4.2 - 2025-06-11
** Bugfix
- ApplSeqNo remains at 1 if OperationMode 0x3 (binary behaviour) is activ
- Offline alarming from Wired to Radio and Radio to Wired does not work
Version 1.4.0 - 2025-02-04
** Bugfix
- Wrong evaluation of the event counter with multiple links between sensor and actuator
- Piggyback ACKs are not evaluated accurately enough.
- Offline alarming from Wired to Radio and Radio to Wired does not work
- Output channels might be set to a wrong state after a long keypress command has received
- If the switch-on and switch-off times in the Easy Profile are set to "Not active" at the same time, the device hangs up.
- If there is no AppAck on a CSC from the CCU, the backup channel is triggered
- HmIP_APP: Send node confusion when using external send nodes
- Answer-Frames are sometimes sent to the wrong IP destination
** Improvement
- Long button press cannot dim in conjunction with a motion detector.
- The time information telegram does not contain a note about the sommer / winter time change.
- If possible, send multicasts only to PARTNER_ALL_WIRED_DEVICES instead of to PARTNER_ALL_DEVICES.
- Modify event counter check to meet current specification
Version 1.2.10 - 2023-06-28
** Improvement
- General improvements - Code optimisation
Version 1.2.8 - 2021-10-26
** Bugfix
- Piggyback ACKs are not evaluated accurately enough.
Version 1.2.6 - 2018-10-15
** Bugfix
- If ResetDisable is set the device hang in abort reset
Version 1.2.4 - 2018-10-08
** Bugfix
- Short key press of key visual leads to a restart, if a factory reset was aborted before
Version 1.2.2 - 2018-09-25
** Bugfix
- If more than one status ACK frame is within the answer queue only the first one is send. Afterwards every new status ACK only triggers the last one
- Statusinfo module creates status ACK telegrams with set ACK, ARR and Boot bits if this is the first status to be sent after startup
- HmIP_APP: Send node confusion when using external send nodes
- Sometimes Statusinfo uses old ApplicationSequenceNumber and Statusinfo with ACK get lost
- Answer-Frames are sometimes sent to the wrong IP destination
- Weekprogram doesn't work correctly if several virtual channels shall be triggered by one switching point
- Profile: Buffer for learned links can overflow
- If the link partner is known, an NAK is sent on ("invalid") frames without ARR bit
- If "Disable Message to AC" is activated and only one channel is addressed, no App-Ack is sent.
Version 1.2.0 - 2018-07-06
** Bugfix
- If an input is configured as a switch, a long keystroke is sent when the input is opened.
- Direct Execution Commands without ARR bit are answered at application level
- Divide maximum number of partners for virtual channels into individual values for virtual A, B and C
** Improvement
- All PowerUp parameters, that are listed in list 3 of the device, must be supported.