C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-eTRV-B-2 - Homematic IP Radiator Thermostat - basic
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.4.2 - 2025-09-23
** Bugfix
- Correction for MANU set point temperature update after window open.
If window open is detected (extern/intern) and during this time the device
get the command "Eco-Mode", the device updated the set point temperature
after window close and "Eco-Mode" off to the window open temperature.
- The device did not report an error after the decalcification run is performed
without a valve.
- Unnecessary valve movements with several window contacts.
If several window contacts are linked to the device, an unwanted valve movement
occurred from the second window open message.
- After a reinclusion, the device sometimes only reacts to a window contact after
deleting and reintegrating.
- Missing valve was not detected after decalcification run.
** Improvement
- The automatic switchover from manu-mode to auto-mode after a restart following
receipt of the first time-info telegram should be deactivated.
Version 1.2.014 - 2024-10-12
** Bugfix
- Optimization of temperature control properties in conjunction with a wall
thermostat.
Version 1.2.012 - 2022-03-17
** First release